MT100

Three power supply modes can be selected freely:

 
*Be directly connected to AC power supply for place with direct insert AC power supply; 
 
*For place without direct insert AC power supply, AC magnetized power supply (AC battery pack) can be used to realize AC magnetization inspection function.

ดาวน์โหลด

Roduct Characteristics


Three power supply modes can be selected freely:
*Be directly connected to AC power supply for place with direct insert AC power supply;
*For place without direct insert AC power supply, AC magnetized power supply (AC battery pack) can be used to realize AC magnetization inspection function.
*DC magnetized power supply (DC battery pack) also can be selected to realize function of DC magnetization.
*AC magnetized power supply (AC battery pack) has the protection function of stable voltage output, over-charge, over-current, over-discharge.
*Automatic power off will be started when the lifting force is insufficient, so as to ensure the detection sensitivity.
*Power display function, which can display current battery capacity, as well as with sound-light alarm function.
*Built-in microcomputer chip, stable output voltage to ensure detection sensitivity.
*Adjustable magnetization intensity
*Special working pockets, which can carry battery pack, magnetic suspension, contrast agent, magnetic yoke probe, etc.


Technical parameter


*Working temperature:  -10~+40℃
*Storage temperature: -20~50℃
*Relative humidity: No condensing<80%
*Operation temperature rise: <18℃
*Duty cycle: >50%
*Sensitivity: type A1 standard specimen 15/50 grooves are clearly displayed
*Minimum AC boost: >4.5kg(44N), maximum AC boost: 7kg (68.6N)
*Minimum DC boost: >18.1kg(177N), maximum DC boost: 23kg (225N)
 

Magnetic yoke flaw detector MT100 MT200
Electrode spacing 0~210mm 0~210mm
Maximum current 2.8A 2.8A
Weight 2.2kg 2.2kg
Main function AC magnetization (direct insert power supply) AC magnetization (direct insert power supply);

DC magnetization (with DC magnetization power supply)